A1000
High performance vector control
Ratings: 200 V Class three-phase 0.4 to 110 kW; 400 V Class three-phase 0.4 to 630 kW
This product is in the process of being discontinued.
- Current vector control, with or without PG
- High starting torque (200% / 0.3 Hz, spd range 1:200 OLV), (200% at 0 r/min, spd range 1:1500 CLV)
- Double rating ND 120%/1min and HD 150%/1 min
- Advanced Auto-Tuning for IM & PM Motors
- Open Loop Control of PM Motors
- Low-noise Low carrier technology
- 10 years lifetime design
- Screw-less terminals
- Control Terminals with memory backup
- 24 VDC control board power supply option
- Fieldbus communications: Modbus, Profibus, CANopen, DeviceNet, ML-II, PROFINET, EtherCAT and EtherNet/IP
- Safety embedded: EN954-1 safety cat. 3, stop category 0, IEC EN 61508 SIL 2 and EN61800-5-1 with EDM
- Regenerative solutions as option
- CE, UL, cUL and TUV
Specifications & ordering info
Product | Drive control method | Drive supply voltage | Max. motor output at constant torque (HD) | Max. motor output at variable torque (ND) | Built in EMC filter | Degree of protection (IP) | Finless type | Compatible motor type | Regenerative solutions | Communication port(s) | Communication option(s) | Description | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 0.55 kW | 0.75 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 0.4 kW 3.2 A, ND: 0.75 kW 3.5 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 0.75 kW | 1.1 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 0.75 kW 5.0 A, ND: 1.1 kW 6.0 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 1.5 kW | 2.2 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 1.5 kW 8.0 A, ND: 2.2 kW 9.6 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 2.2 kW | 3 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 2.2 kW 11.0 A, ND: 3.0 kW 12.0 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 4 kW | 5.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 4.0 kW 17.5 A, ND: 5.5 kW 21.0 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 5.5 kW | 7.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 5.5 kW 25.0 A, ND: 7.5 kW 30.0 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 7.5 kW | 11 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 7.5 kW 33.0 A, ND: 11.0 kW 40.0 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 11 kW | 15 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 11 kW 47.0 A, ND: 15.0 kW 56.0 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 15 kW | 18.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 15 kW 60.0 A, ND: 18.5 kW 69.0 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 18.5 kW | 22 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 18.5 kW 75 A, ND: 22 kW 81 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 22 kW | 30 kW | No | IP00 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 22 kW 85 A, ND: 30 kW 110 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 30 kW | 37 kW | No | IP00 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 30 kW 115 A, ND: 37 kW 138 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 37 kW | 45 kW | No | IP00 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 37 kW 145 A, ND: 45 kW 169 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 45 kW | 55 kW | No | IP00 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 45 kW 180 A, ND: 55 kW 211 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 55 kW | 75 kW | No | IP00 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 55 kW 215 A, ND: 75 kW 250 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 75 kW | 90 kW | No | IP00 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3-phase 200 V, HD: 75 kW 283 A, ND: 90 kW 312 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 90 kW | 110 kW | No | IP00 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 90 kW 346 A, ND: 110 kW 360 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 110 kW | 110 kW | No | IP00 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 200 V, HD: 110 kW 415 A, ND: 110 kW 415 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 0.55 kW | 0.75 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 400 V, HD: 0.55 kW 1.8 A, ND: 0.75 kW 2.1 A, max. output freq. 400Hz | |
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 1.1 kW | 1.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor | As inverter option | MODBUS Slave, Serial RS-422, Serial RS-485 | CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, MECHATROLINK II Slave, MODBUS/TCP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | A1000 inverter: 3~ 400 V, HD: 0.75 kW 3.4 A, ND: 1.5 kW 4.1 A, max. output freq. 400Hz |
Accessories
Regenerative accessories

D1000 kit - DC Supply with Regenerative Active Front End system

Regenerative DC bus supply unit (D1000)
Rated output capacity (kW)1 |
||||||||||||
EMC filter
Low harmonic filter
Heat loss (W)2 |
||||||||||||
R1000 kit - Regenerative Braking unit system

Regenerative Braking unit (R1000)
Rated output capacity (kW)3 |
||||||||||||||||
Current suppression reactor
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Ota minuun yhteyttä A1000

Kiitos yhteydenotostasi. Otamme teihin yhteyttä mahdollisimman pian.
Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.
DownloadTarjous A1000
Tällä lomakkeella voit pyytää tarjouksen valitsemastasi tuotteesta. Täytäthän kaikki *-merkityt kentät. Henkilökohtaisia tietojasi käsitellään luottamuksellisesti.

Kiitos tarjouspyynnöstä. Toimitamme tarvittavat tiedot teille mahdollisimman pian.
Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.
Download