K8AK-LS | Omron, Suomi

Login

Please use more than 6 characters. Forgot your password? Click here to reset.

Change password

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download

Register

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download

Thank you for your interest

You now have access to K8AK-LS

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

K8AK-LS

22.5 mm wide conductive level controller

The K8AK-LS1 is a conductive level controller in a 22.5 mm wide industrial housing. Via DIP switches its function (supply or drainage) can be selected. This product is for single- or two-point level control.

Time delay function up to 10 sSupply voltages: 24 VAC/DC and 100 to 240 VACControl output: Relay 5 A at 250 VAC resistive loadProbes cable length: Max. 100 m from controllerLED indicator: Green for power ON, yellow for output relay

Specifications & ordering info

Ordering information

Supply voltage

Order code

24 VAC/VDC

K8AK-LS1 24VAC/DC

100 to 240 VAC

K8AK-LS1 100-240 VAC

Accessories

Electrode holders

Applications

Mounting style

Insulator material

Max. temperature

Number of electrodes

Order code

For city water and other general use.
Easy-to-replace separate versions for maintenance.

Flange

Phenol resin

70°C

3

PS-3S

When mounting space is limited.
Special 3-pole holder of small size and light weight.

Screw

Phenol resin

3, 300 mm

3, 1000 mm

PS-31-300MM
PS-31-1000MM

Use for sewage, sea water, etc.,
having a low specific resistance.

Flange

PPS

150°C (without water drips or vapour on the electrode holder surface)

1

BF-1

For resistance to high pressure.
Use in tanks with high temperature or pressure.

Screw

Fluoro resin

250°C (without water drips or vapour on the surface of the electrode holder)

1

BS-1

Electrode separators

Number of electrodes

Order code

 

1

F03-14 1P

3

F03-14 3P

Electrodes, connecting, and lock nuts

Applicable liquids

Material

Component

Indication mark

Inscription

Order code

Purified city water, industrial water, sewage

Equivalent to SUS304
(AISI-304)

Electrode (1 m long)

1 line

-

F03-01 SUS201

Connecting nut

-

-

F03-02 SUS201

Lock nut

-

-

F03-03 SUS201

Purified city water, industrial water, sewage,
dilute alkaline solution

SUS316
(AISI-316)

Electrode (1 m long)

2 lines

-

F03-01 SUS316

Connecting nut

-

6

F03-02 SUS316

Lock nut

-

316

F03-03 SUS316

Specifications

Item

K8AK-LS

Ambient operating temperature

-20 to 60°C (with no condensation or icing)

Storage temperature

-25 to 65°C (with no condensation or icing)

Operating voltage range

85% to 110% of rated operating voltage

Rated power supply frequency

50/60 Hz (AC power supply)

Output relays

Resistive load

5 A at 250 VAC or at 30 VDC

Maximum contact voltage

250 VAC or 30 VDC

Maximum contact current

5 A

Maximum switching capacity

1,250 VA, 150 W

Mechanical life

10,000,000 operations

Electrical life

50,000 operations at 5 A, 250 VAC or 30 VDC

Degree of protection

Terminal section: IP20

Case material

PC and ABS

Weight

Approx. 150 g

Operating resistance

10 kΩ to 100 kΩ (variable)

Reset resistance

250 kΩ max.

Response time

Approx. 0.1 to 10 s (variable)

Cable length

100 m max. with completely insulated (600 V) cabtire cable with 3 conductors (0.75 mm2)

Indicators

Green LED: Power, Yellow LED: Control output

Applicable standards

Conforming standards

EN 61010-1
Installation environment (pollution level 2, installation category II)

EMC

EN 61326-1

Safety standards

EN 60664-1UL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA and CCC

Size in mm (H × W × D)

90 × 22.5 × 100

How can we help you?

If you have a question or would like to ask for a quote, please contact us or send a request.

0207 464 200
Contact us

Ota minuun yhteyttä

Täytäthän kaikki *-merkityt kentät. Henkilökohtaisia tietojasi käsitellään luottamuksellisesti.

Text area error notification

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Checkbox error notification

Checkbox error notification

Kiitos yhteydenotostasi. Otamme teihin yhteyttä mahdollisimman pian.

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download
Pricing
Request a quote

Tarjouspyyntö

Tällä lomakkeella voit pyytää tarjouksen valitsemastasi tuotteesta. Täytäthän kaikki *-merkityt kentät. Henkilökohtaisia tietojasi käsitellään luottamuksellisesti.

K8AK-LS

Text error notification

Text error notification

Text error notification

Select notification error

Select notification error

Country error notification

Text error notification

Text area error notification

Checkbox error notification

Checkbox error notification

Kiitos tarjouspyynnöstä. Toimitamme tarvittavat tiedot teille mahdollisimman pian.

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download