Login

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download

Register

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download

Thank you for your interest

You now have access to E3NX-MA

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

E3NX-MA

E3NX-MA

Smart Fiber Amplifier Units

2-channel Amplifier reduces installation space by half. Downsized Equipment and Control Panels

  • The new 2 channel fiber amplifier unit has two-unit functions in the dimensions of the general one-unit, contributing to downsizing your equipment and control panels.
  • Performance with highly stable detection and even two channels. From transparent objects to low-reflective workpieces.
  • Easy to set the light intensity and threshold automatically.
  • Wire-saving Connector models that reduce wiring work.

Specifications & ordering info

Ordering information

Type

Connecting method

Appearance

Inputs/outputs

Order code

NPN output

PNP output

2-channel models

Standard Type

Pre-wired (2 m)

 

2 outputs

E3NX-MA11

E3NX-MA41

Wire-saving Connector

 

2 outputs

E3NX-MA6

E3NX-MA8

Model for Sensor Communications Unit1

Connector for Sensor Communications Unit

 

E3NX-MA0

Specifications

Type

Standard Type

Model for Sensor Communications Unit

NPN output

E3NX-MA11

E3NX-MA6

E3NX-MA0

PNP output

E3NX-MA41

E3NX-MA8

Connecting method

Pre-wired

Wire-saving Connector

Connector for Sensor Communications Unit

Inputs/outputs

Outputs

2 outputs

2

External inputs

Light source (wavelength)

Red, 4-element LED (625 nm)

Response time

Super-high-speed mode (SHS)

Operate or reset: 100 μs

High-speed mode (HS)

Operate or reset: 450 μs

Standard mode (Stnd)

Operate or reset: 1 ms

Giga-power mode (GIGA)

Operate or reset: 16 ms

Sensitivity adjustment

Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment

Maximum connectable Units

30

With E3NW-ECT: 30 units3

With E3NW-CCL: 16 units

No. of Units for mutual interference prevention4 5

9

Functions

Automatic power control (APC)

Always enabled.

Dynamic power control (DPC)

Provided

Timer

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms

Zero reset

Negative values can be displayed. (Threshold value is shifted.)

Resetting settings 6

Select from initial reset (factory defaults) or user reset (saved settings).

Eco mode

Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).

Bank switching

Select from banks 1 to 4.

Power tuning

Select from ON or OFF.

Output 1

Select from normal detection mode or area detection mode.

Output 2

Select from normal detection mode, AND output mode, OR output mode, XOR output mode,
GAP output mode, Falling synchronization mode, Rising synchronization mode or area detection mode.

Hysteresis width

Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.

Ambient illumination (Receiver side)

Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.

Ambient temperature range7

Operating:

Groups of 1 or 2 Amplifier Units: −25 to 55°C,
Groups of 3 to 10 Amplifier Units: −25 to 50°C,
Groups of 11 to 16 Amplifier Units: −25 to 45°C,
Groups of 17 to 30 Amplifier Units: −25 to 40°C

Storage:
−30 to 70°C (with no icing or condensation)

Operating:

Groups of 1 or 2 Amplifier Units: 0 to 55°C,
Groups of 3 to 10 Amplifier Units: 0 to 50°C,
Groups of 11 to 16 Amplifier Units: 0 to 45°C,
Groups of 17 to 30 Amplifier Units: 0 to 40°C

Storage:
−30 to 70°C (with no icing or condensation)

Ambient humidity range

Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above

Insulation resistance

20 MΩ min. (at 500 VDC)

Vibration resistance (destruction)

10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

500 m/s² for 3 times each in X, Y, and Z directions

150 m/s² for 3 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP50 (with Protective Cover attached)

Weight
(packed state/Sensor only)

Approx. 115 g/

approx. 75 g

Approx. 60g/

approx. 20g

Approx. 65 g/

approx. 25 g

Materials

Case

Polycarbonate (PC)

Cover

Polycarbonate (PC)

Cable

PVC


1. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.
2. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
3. When connected to an OMRON NJ-series Controller.
4. The tuning will not change the number of units.
The least unit count among the mutual interference prevention units of E3NX and E3NC.
Check the mutual interference prevention unit count and response speed of each model.
5. The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.
6. The bank is not reset by the user reset function or saved by the user save function.
7. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
1. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.
2. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
3. When connected to an OMRON NJ-series Controller.
4. The tuning will not change the number of units.
The least unit count among the mutual interference prevention units of E3NX and E3NC.
Check the mutual interference prevention unit count and response speed of each model.
5. The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.
6. The bank is not reset by the user reset function or saved by the user save function.
7. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.

How can we help you?

If you have a question or would like to ask for a quote, please contact us or send a request.

0207 464 200
Contact us

Ota minuun yhteyttä E3NX-MA

E3NX MA prod

Täytäthän kaikki *-merkityt kentät. Henkilökohtaisia tietojasi käsitellään luottamuksellisesti.

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Text area error notification

Checkbox error notification

Checkbox error notification

Kiitos yhteydenotostasi. Otamme teihin yhteyttä mahdollisimman pian.

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download
0207 464 200
0207 464 200
Request quotation
Request quotation

Tarjous E3NX-MA

Tällä lomakkeella voit pyytää tarjouksen valitsemastasi tuotteesta. Täytäthän kaikki *-merkityt kentät. Henkilökohtaisia tietojasi käsitellään luottamuksellisesti.

E3NX MA prod

Henkilökohtaiset tiedot

E3NX-MA

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Tarjouksen yksityiskohdat

Select notification error

Select notification error

Text area error notification

Checkbox error notification

Checkbox error notification

Kiitos tarjouspyynnöstä. Toimitamme tarvittavat tiedot teille mahdollisimman pian.

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download
Request quotation
Request quotation

Features

Logic operations without PLC

e3nx fa amplifier prod

The AND, OR, XOR and GAP functionality among others for both fiber channels allows simple signal processing without the need for a PLC. This allows the addition of sensor checks to machines without reprogramming the PLC.

Space & cost reduction

e3nx fa operations prod

The 2 in 1 amplifier replaces two standard amplifiers reducing space requirements and hardware cost.