Login

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download

Register

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download

Thank you for your interest

You now have access to G7SA

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

G7SA

G7SA

Relays with forcibly guided contacts

The slim G7SA relay family with forcibly guided contacts is available as a four or six-pole type in various contact combinations and offers reinforced insulation. Terminals are arranged for easy PCB layout. It can be soldered directly to a PCB or used together with the P7SA sockets.

  • Forcibly guided contacts
  • Conforms to EN 50205
  • 6 A at 240 VAC and 6A at 24 VDC for resistive loads
  • Reinforced insulation between inputs, outputs and poles
  • 4- and 6-pole relays available
  • Sockets available with Push-In technology

Specifications & ordering info

Ordering information

Relays with forcibly guided contacts

Type

Sealing

Poles

Contacts

Rated voltage

Order code

Standard

Flux-tight

4 poles

3PST-NO, SPST-NC

24 VDC1

G7SA-3A1B

DPST-NO, DPST-NC

G7SA-2A2B

6 poles

5PST-NO, SPST-NC

G7SA-5A1B

4PST-NO, DPST-NC

G7SA-4A2B

3PST-NO, 3PST-NC

G7SA-3A3B

Sockets

Mounting

Terminal type

LED indicator

Poles

Coil rated voltage

Order code

Front-
mounting

Push-In Plus terminals

Yes

4 poles

24 VDC

P7SA-10F-ND-PU

6 poles

P7SA-14F-ND-PU

Screw terminals

Yes

4 poles

P7SA-10F-ND

6 poles

P7SA-14F-ND

No

4 poles

P7SA-10F

6 poles

P7SA-14F

Back-
mounting

PCB terminals

No

4 poles

P7SA-10P

6 poles

P7SA-14P

Specifications

Coil

Rated voltage

Rated current

Coil resistance

Must-operate voltage

Must-release voltage

Max. voltage

Power consumption

24 VDC

4 poles: 15 mA

6 poles: 20.8 mA

4 poles: 1,600 Ω
6 poles: 1,152 Ω

75% max. (V)

10% min. (V)

110% (V)

4 poles: Approx. 360 mW
6 poles: Approx. 500 mW

Note: Refer to datasheet for details

Contacts

Load

Resistive load (cos φ = 1)

Rated load

6 A at 250 VAC, 6 A at 30 VDC

Rated carry current

6 A

Max. switching voltage

250 VAC, 125 VDC

Max. switching current

6 A

Max. switching capacity (reference value)

1,500 VA, 180 W

Relays with forcibly guided contacts

Contact resistance

100 mΩ max. (The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.)

Operating time 2

20 ms max.

Response time 1

10 ms max.
(The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF.)

Release time 1

20 ms max.

Insulation resistance

100 MΩ min. (at 500 VDC) (The insulation resistance was measured with a 500 VDC megger at the same places that the dielectric strength was
measured.)

Dielectric strength 3 4

Between coil contacts/different poles: 4,000 VAC, 50/60 Hz for 1 min
(2,500 VAC between poles 3-4 in 4-pole Relays or poles 3-5, 4-6, and 5-6 in 6-pole Relays.)

Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min

Durability

Mechanical

10,000,000 operations min. (at approx. 36,000 operations/hr)

Electrical

100,000 operations min. (at the rated load and approx. 1,800 operations/hr)

Min. permissible load5

5 VDC, 1 mA (reference value)

Ambient temperature 6

Operating: −40 to 85°C (with no icing or condensation)

Ambient humidity

Operating: 35 to 85%

Approved standards

EN61810-1 (IEC61810-1), EN50205, UL508, CSA22.2 No. 14

Note: The values listed above are initial values.

 

Please check Omron in the Internet for updated information on product reliability data and the SISTEMA libraries: http://industrial.omron.eu/safety


1. 12 VDC, 21 VDC, 48 VDC are available on request.
2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not included.
3. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and pole 6 refers to terminals 63-64.
4. When using a P7SA socket, the dielectric strength between coil contacts/different poles is 2,500 VAC, 50/60 Hz for 1 min.
5. Min. permissible load is for a switching frequency of 300 operations/min.
6. When operating at a temperature between 70°C and 85°C, reduce the rated carry current (6 A at 70°C or less) by 0.1 A for each degree above 70°C.
1. 12 VDC, 21 VDC, 48 VDC are available on request.
2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not included.
3. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and pole 6 refers to terminals 63-64.
4. When using a P7SA socket, the dielectric strength between coil contacts/different poles is 2,500 VAC, 50/60 Hz for 1 min.
5. Min. permissible load is for a switching frequency of 300 operations/min.
6. When operating at a temperature between 70°C and 85°C, reduce the rated carry current (6 A at 70°C or less) by 0.1 A for each degree above 70°C.

How can we help you?

If you have a question or would like to ask for a quote, please contact us or send a request.

0207 464 200
Contact us

Ota minuun yhteyttä G7SA

g7sa img prod

Täytäthän kaikki *-merkityt kentät. Henkilökohtaisia tietojasi käsitellään luottamuksellisesti.

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Text area error notification

Checkbox error notification

Checkbox error notification

Kiitos yhteydenotostasi. Otamme teihin yhteyttä mahdollisimman pian.

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download
0207 464 200
0207 464 200
Request quotation
Request quotation

Tarjous G7SA

Tällä lomakkeella voit pyytää tarjouksen valitsemastasi tuotteesta. Täytäthän kaikki *-merkityt kentät. Henkilökohtaisia tietojasi käsitellään luottamuksellisesti.

g7sa img prod

Henkilökohtaiset tiedot

G7SA

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Tarjouksen yksityiskohdat

Select notification error

Select notification error

Text area error notification

Checkbox error notification

Checkbox error notification

Kiitos tarjouspyynnöstä. Toimitamme tarvittavat tiedot teille mahdollisimman pian.

Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.

Download
Request quotation
Request quotation

Downloads