Manual Motor Starter (Motor Protection Circuit Breaker)
MPCB system, protection from Overload, Phase failure and Short Circuit
- Push-In Plus wiring technology saves wiring and maintenance time
- In combination with magnetic contactor model J7KC, it is ideal for control of motors to AC-3 class, 2.2 kW (200 to 240 VAC) * or 5.5 kW (380 to 440 VAC).
- Rocker switch (standard type) and rotary switch (high-performance type)
- High breaking capacity (Max100 kA/440 VAC)
- Equipped with a dial cover as standard to protect accidental setting changes. Lockable with a padlock to ensure safety at startup.
- Certified as compliant with the main safety standards
Specifications & ordering info
Product | Rated power AC2, AC3 at 400 V [kW] | Short-circuit breaking capacity at 3 ~ 400 V [kA] | Terminal | Product Width (unpacked) | Product Height (unpacked) | Product Depth (unpacked) | Control type | Description | |
---|---|---|---|---|---|---|---|---|---|
|
0.2 kW | 100 kA | Push-in | 45 mm | 130 mm | 74.7 mm | Switch type | Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 0.63 - 1.00 A, H×W×D 130 x 45 x 71 mm |
|
|
7.5 kW | 10 kA | Push-in | 45 mm | 130 mm | 74.7 mm | Switch type | Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 11 - 16 A, H×W×D 130 x 45 x 71 mm |
|
|
0.4 kW | 100 kA | Push-in | 45 mm | 130 mm | 74.7 mm | Switch type | Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 1 - 1.6 A, H×W×D 130 x 45 x 71 mm |
|
|
2.2 kW | 50 kA | Push-in | 45 mm | 130 mm | 74.7 mm | Switch type | Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 4 - 6.3 A, H×W×D 130 x 45 x 71 mm |
|
|
0.02 kW | 100 kA | Push-in | 45 mm | 130 mm | 74.7 mm | Switch type | Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 0.10 - 0.16 A, H×W×D 130 x 45 x 71 mm |
|
|
0.12 kW | 100 kA | Push-in | 45 mm | 130 mm | 74.7 mm | Switch type | Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 0.40 - 0.63 A, H×W×D 130 x 45 x 71 mm |
|
|
3.7 kW | 50 kA | Push-in | 45 mm | 130 mm | 94.7 mm | Rotary type | Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 6.3 - 10 A, H×W×D 130 x 45 x 90.8 mm |
|
|
11 kW | 35 kA | Push-in | 45 mm | 130 mm | 94.7 mm | Rotary type | Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 14 - 20 A, H×W×D 130 x 45 x 90.8 mm |
|
|
0.02 kW | 100 kA | Push-in | 45 mm | 130 mm | 94.7 mm | Rotary type | Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 0.10 - 0.16 A, H×W×D 130 x 45 x 90.8 mm |
|
|
0.06 kW | 100 kA | Push-in | 45 mm | 130 mm | 94.7 mm | Rotary type | Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 0.16 - 0.25 A, H×W×D 130 x 45 x 90.8 mm |
|
|
0.1 kW | 100 kA | Push-in | 45 mm | 130 mm | 94.7 mm | Rotary type | Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 0.25 - 0.40 A, H×W×D 130 x 45 x 90.8 mm |
|
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Ota minuun yhteyttä J7MC
Kiitos yhteydenotostasi. Otamme teihin yhteyttä mahdollisimman pian.
Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.
DownloadTarjous J7MC
Tällä lomakkeella voit pyytää tarjouksen valitsemastasi tuotteesta. Täytäthän kaikki *-merkityt kentät. Henkilökohtaisia tietojasi käsitellään luottamuksellisesti.
Kiitos tarjouspyynnöstä. Toimitamme tarvittavat tiedot teille mahdollisimman pian.
Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.
Download