MX2
Born to Drive Machines
Specifically created for your application, the MX2 was developed to harmonise advanced motor and machine control. Thanks to its advanced design and algorithms, the MX2 provides smooth control down to zero speed, plus precise operation for cyclic operations and torque control capability in open loop.
- High starting torque: 200% at 0.5 Hz
- Torque control in open loop vector
- Double rating VT 120%/1 min and CT 150%/ 1 min
- IM & PM motor control
- Safety conforming to ISO13849-1 Category
- 3 performance level PLD
- Built-in Logic programming
- Positioning functionality
- Integrated at Omron machine Automation solution
- Fieldbus communications: EtherCAT, Modbus, DeviceNet, Profibus, CompoNet, MECHATROLINK-II and EtherNet/IP
- Ratings: 200 V single-phase from 0.1 to 2.2 kW, 200 V three-phase from 0.1 to 15.0 kW, 400 V three-phase from 0.4 to 15.0 kW.
Specifications & ordering info
Ordering information
3G3MX2
Specifications | Order code | |||||
---|---|---|---|---|---|---|
Voltage class | Constant torque | Variable torque | Standard | Finless | ||
Max motor kW | Rated current A | Max motor kW | Rated current A | |||
Single-phase 200 V |
0.1 | 1.0 | 0.2 | 1.2 | 3G3MX2-AB001-E | 3G3MX2-AB001-P-E |
0.2 | 1.6 | 0.4 | 1.9 | 3G3MX2-AB002-E | 3G3MX2-AB002-P-E | |
0.4 | 3.0 | 0.55 | 3.5 | 3G3MX2-AB004-E | 3G3MX2-AB004-P-E | |
0.75 | 5.0 | 1.1 | 6.0 | 3G3MX2-AB007-E | 3G3MX2-AB007-P-E | |
1.5 | 8.0 | 2.2 | 9.6 | 3G3MX2-AB015-E | 3G3MX2-AB015-P-E | |
2.2 | 11.0 | 3.0 | 12.0 | 3G3MX2-AB022-E | 3G3MX2-AB022-P-E | |
Three-phase 200 V |
0.1 | 1.0 | 0.2 | 1.2 | 3G3MX2-A2001-E | 3G3MX2-A2001-P-E |
0.2 | 1.6 | 0.4 | 1.9 | 3G3MX2-A2002-E | 3G3MX2-A2002-P-E | |
0.4 | 3.0 | 0.55 | 3.5 | 3G3MX2-A2004-E | 3G3MX2-A2004-P-E | |
0.75 | 5.0 | 1.1 | 6.0 | 3G3MX2-A2007-E | 3G3MX2-A2007-P-E | |
1.5 | 8.0 | 2.2 | 9.6 | 3G3MX2-A2015-E | 3G3MX2-A2015-P-E | |
2.2 | 11.0 | 3.0 | 12.0 | 3G3MX2-A2022-E | 3G3MX2-A2022-P-E | |
3.7 | 17.5 | 5.5 | 19.6 | 3G3MX2-A2037-E | 3G3MX2-A2037-P-E | |
5.5 | 25.0 | 7.5 | 30.0 | 3G3MX2-A2055-E | – | |
7.5 | 33.0 | 11 | 40.0 | 3G3MX2-A2075-E | – | |
11 | 47.0 | 15 | 56.0 | 3G3MX2-A2110-E | – | |
15 | 60.0 | 18.5 | 69.0 | 3G3MX2-A2150-E | – | |
Three-phase 400 V |
0.4 | 1.8 | 0.75 | 2.1 | 3G3MX2-A4004-E | 3G3MX2-A4004-P-E |
0.75 | 3.4 | 1.5 | 4.1 | 3G3MX2-A4007-E | 3G3MX2-A4007-P-E | |
1.5 | 4.8 | 2.2 | 5.4 | 3G3MX2-A4015-E | 3G3MX2-A4015-P-E | |
2.2 | 5.5 | 3.0 | 6.9 | 3G3MX2-A4022-E | 3G3MX2-A4022-P-E | |
3.0 | 7.2 | 4.0 | 8.8 | 3G3MX2-A4030-E | 3G3MX2-A4030-P-E | |
4.0 | 9.2 | 5.5 | 11.1 | 3G3MX2-A4040-E | 3G3MX2-A4040-P-E | |
5.5 | 14.8 | 7.5 | 17.5 | 3G3MX2-A4055-E | – | |
7.5 | 18.0 | 11 | 23.0 | 3G3MX2-A4075-E | – | |
11 | 24.0 | 15 | 31.0 | 3G3MX2-A4110-E | – | |
15 | 31.0 | 18.5 | 38.0 | 3G3MX2-A4150-E | – |
① Line filters
Inverter | Standard line filter | Low leakage line filter | |||||||
---|---|---|---|---|---|---|---|---|---|
Rasmi | Schaffner | Rasmi | Schaffner | ||||||
Voltage | Model 3G3MX2-_ | Order code AX-FIM |
Current (A) | Order code AX-FIM |
Current (A) | Order code AX-FIM |
Current (A) | Order code AX-FIM |
Current (A) |
1Phase 200VAC |
AB001 / AB002 / AB004 | 1010-RE | 10 | 1010-SE-V1 | 8 | 1010-RE-LL | 10 | 1010-SE-LL | 10 |
AB007 | 1014-RE | 14 | 1014-SE-V1 | 14 | 1014-RE-LL | 14 | 1014-SE-LL | 14 | |
AB015 / AB022 | 1024-RE | 24 | 1024-SE-V1 | 27 | 1024-RE-LL | 24 | 1024-SE-LL | 24 | |
3Phase 200VAC |
A2001 / A2002 / A2004 / A2007 |
2010-RE | 10 | 2010-SE-V1 | 7.8 | 2010-RE-LL | 10 | – | – |
A2015 / A2022 | 2020-RE | 20 | 2020-SE-V1 | 16 | 2020-RE-LL | 20 | 2020-SE-LL | 20 | |
A2037 | 2030-RE | 30 | 2030-SE-V1 | 25 | 2030-RE-LL | 30 | 2030-SE-LL | 30 | |
A2055 / A2075 | 2060-RE | 60 | 2060-SE-V1 | 50 | 2060-RE-LL | 60 | 2060-SE-LL | 50 | |
A2110 | 2080-RE | 80 | 2080-SE-V1 | 70 | 2080-RE-LL | 80 | – | – | |
A2150 | 2100-RE | 100 | 2100-SE-V1 | 75 | 2100-RE-LL | 100 | – | – | |
3Phase 400VAC |
A4004 / A4007 | 3005-RE | 5 | 3005-SE-V1 | 6 | 3005-RE-LL | 5 | 3005-SE-LL | 5 |
A4015 / A4022 / A4030 | 3010-RE | 10 | 3010-SE-V1 | 12 | 3010-RE-LL | 10 | 3010-SE-LL | 10 | |
A4040 | 3014-RE | 14 | 3014-SE-V1 | 15 | 3014-RE-LL | 14 | 3014-SE-LL | 15 | |
A4055 / A4075 | 3030-RE | 30 | 3030-SE-V1 | 29 | 3030-RE-LL | 30 | 3030-SE-LL | 30 | |
A4110 / A4150 | 3050-RE | 50 | 3050-SE-V1 | 48 | 3050-RE-LL | 50 | 3050-SE-LL | 50 |
① Input AC reactors
Inverter | AC Reactor | |
---|---|---|
Voltage | Model 3G3MX2-_ | Order code |
1-Phase 200 VAC |
AB002/AB004 | AX-RAI02000070-DE |
AB007 | AX-RAI01700140-DE | |
AB015 | AX-RAI01200200-DE | |
AB022 | AX-RAI00630240-DE | |
3-Phase 200 VAC |
A2002/A2004/A2007 | AX-RAI02800080-DE |
A2015/A2022/A2037 | AX-RAI00880200-DE | |
A2055/A2075 | AX-RAI00350335-DE | |
A2110/A2150 | AX-RAI00180670-DE | |
3-Phase 400 VAC |
A4004/A4007/A4015 | AX-RAI07700050-DE |
A4022/A4030/A4040 | AX-RAI03500100-DE | |
A4055/A4075 | AX-RAI01300170-DE | |
A4110/A4150 | AX-RAI00740335-DE |
① DC reactors
200 V single-phase | 200 V three-phase | 400 V three-phase | |||
---|---|---|---|---|---|
Inverter | Order code | Inverter | Order code | Inverter | Order code |
3G3MX2-AB001 | AX-RC10700032-DE | 3G3MX2-A2001 | AX-RC21400016-DE | 3G3MX2-A4004 | AX-RC43000020-DE |
3G3MX2-AB002 | 3G3MX2-A2002 | 3G3MX2-A4007 | AX-RC27000030-DE | ||
3G3MX2-AB004 | AX-RC06750061-DE | 3G3MX2-A2004 | AX-RC10700032-DE | 3G3MX2-A4015 | AX-RC14000047-DE |
3G3MX2-AB007 | AX-RC03510093-DE | 3G3MX2-A2007 | AX-RC06750061-DE | 3G3MX2-A4022 | AX-RC10100069-DE |
3G3MX2-AB015 | AX-RC02510138-DE | 3G3MX2-A2015 | AX-RC03510093-DE | 3G3MX2-A4030 / A4040 | AX-RC06400116-DE |
3G3MX2-AB022 | AX-RC01600223-DE | 3G3MX2-A2022 | AX-RC02510138-DE | 3G3MX2-A4055 | AX-RC04410167-DE |
– | 3G3MX2-A2037 | AX-RC01600223-DE | 3G3MX2-A4075 | AX-RC03350219-DE | |
3G3MX2-A2055 | AX-RC01110309-DE | 3G3MX2-A4110 | AX-RC02330307-DE | ||
3G3MX2-A2075 | AX-RC00840437-DE | 3G3MX2-A4150 | AX-RC01750430-DE | ||
3G3MX2-A2110 | AX-RC00590614-DE | – | |||
3G3MX2-A2150 | AX-RC00440859-DE |
① Chokes
Diameter | Description | Order code |
---|---|---|
21 | For 2.2 KW motors or below | AX-FER2102-PE |
28 | For 15 KW motors or below | AX-FER2815-PE |
50 | For 45 KW motors or below | AX-FER5045-PE |
① Output AC reactor
Inverter | AC Reactor | |
---|---|---|
Voltage | Model 3G3MX2-_ | Order code |
200 VAC | AB001/AB002/AB004/A2001/ A2002/A2004 |
AX-RAO11500026-DE |
AB007/A2007 | AX-RAO07600042-DE | |
AB015/A2015 | AX-RAO04100075-DE | |
AB022/A2022 | AX-RAO03000105-DE | |
A2037 | AX-RAO01830160-DE | |
A2055 | AX-RAO01150220-DE | |
A2075 | AX-RAO00950320-DE | |
A2110 | AX-RAO00630430-DE | |
A2150 | AX-RAO00490640-DE | |
400 VAC | A4004/A4007/A4015 | AX-RAO16300038-DE |
A4022 | AX-RAO11800053-DE | |
A4030/A4040 | AX-RAO07300080-DE | |
A4055 | AX-RAO04600110-DE | |
A4075 | AX-RAO03600160-DE | |
A4110 | AX-RAO02500220-DE | |
A4150 | AX-RAO02000320-DE |
② Accessories
Types | Description | Functions | Order code |
---|---|---|---|
Digital operator | LCD remote operator | 5 Line LCD remote operator with copy function, cable length max. 3m. | AX-OP05-E |
Remote operator cable | 3 meters cable for connecting remote operator | 3G3AX-CAJOP300-EE | |
LED remote operator | LED remote operator, cable length max. 3m | 3G3AX-OP01 | |
Mounting kit for LED operator | Mounting kit for LED operator on panel | 4X-KITMINI | |
Operator holder | Holder to put the AX-OP05-E inside of the cabinet | 3G3AX-OP05-H-E | |
Accessories | PC configuration cable | Mini USB to USB connector cable | AX-CUSBM002-E |
③ Communication option boards
Description | Functions | Order code |
---|---|---|
Profibus option card | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through communications with the host controller. |
3G3AX-MX2-PRT |
DeviceNet option card | 3G3AX-MX2-DRT | |
EtherCAT option card | 3G3AX-MX2-ECT | |
CompoNet option card | 3G3AX-MX2-CRT | |
MECHATROLINK-II option card | 3G3AX-MX2-MRT | |
EtherNet/IP option card | 3G3AX-MX2-EIP | |
Extra input/output option board |
1 analog voltage input, 1 analog current input, 1 analog voltage output, 8 discrete logic inputs, 4 discrete logic outputs |
3G3AX-MX2-EIO15-E |
④ Braking unit, braking resistor unit
Inverter | Braking resistor unit | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Voltage | Max. motor kW |
Inverter 3G3MX2_ | Connectable min. resistance W |
Inverter mounted type (3% ED, 10sec max) |
Braking torque % |
Inverter mounted type (10% ED, 10sec max) |
Braking torque % |
|||
1-phase | 3-phase | Order code | Resist Ω | Order code | Resist Ω | |||||
200 V (Single-/ Three-phase) |
0.12 | B001 | 2001 | 100 | AX-REM00K1400-IE | 400 | 200 | AX-REM00K1400-IE | 400 | 200 |
0.25 | B002 | 2002 | 180 | 180 | ||||||
0.55 | B004 | 2004 | AX-REM00K1200-IE | 200 | 180 | AX-REM00K1200-IE | 200 | 180 | ||
1.1 | B007 | 2007 | 50 | 100 | AX-REM00K2070-IE | 70 | 200 | |||
1.5 | B015 | 2015 | AX-REM00K2070-IE | 70 | 140 | AX-REM00K4075-IE | 75 | 130 | ||
2.2 | B022 | 2022 | 35 | 90 | AX-REM00K4035-IE | 35 | 180 | |||
4.0 | – | 2040 | AX-REM00K4075-IE | 75 | 50 | AX-REM00K6035-IE | 35 | 100 | ||
5.5 | – | 2055 | 20 | AX-REM00K4035-IE | 35 | 75 | AX-REM00K9020-IE | 20 | 150 | |
7.5 | – | 2075 | 17 | 55 | AX-REM01K9017-IE | 17 | 110 | |||
11 | – | 2110 | AX-REM00K6035-IE | 35 | 40 | AX-REM02K1017-IE | 17 | 75 | ||
15 | – | 2150 | 10 | AX-REM00K9017-IE | 17 | 55 | AX-REM03K5010-IE | 10 | 95 | |
400 V (Three-phase) |
0.55 | – | 4004 | 180 | AX-REM00K1400-IE | 400 | 200 | AX-REM00K1400-IE | 400 | 200 |
1.1 | – | 4007 | 200 | 200 | ||||||
1.5 | – | 4015 | AX-REM00K1200-IE | 200 | 190 | AX-REM00K2200-IE | 200 | 190 | ||
2.2 | – | 4022 | 100 | AX-REM00K2200-IE | 200 | 130 | AX-REM00K5120-IE | 120 | 200 | |
3.0 | – | 4030 | AX-REM00K2120-IE | 120 | 160 | 160 | ||||
4.0 | – | 4040 | 120 | AX-REM00K6100-IE | 100 | 140 | ||||
5.5 | – | 4055 | 70 | AX-REM00K4075-IE | 75 | 140 | AX-REM00K9070-IE | 70 | 150 | |
7.5 | – | 4075 | 100 | AX-REM01K9070-IE | 70 | 110 | ||||
11 | – | 4110 | AX-REM00K6100-IE | 100 | 50 | AX-REM02K1070-IE | 70 | 75 | ||
15 | – | 4150 | 35 | AX-REM00K9070-IE | 70 | 55 | AX-REM03K5035-IE | 35 | 110 |
⑤ Computer software
Description | Installation | Order code |
---|---|---|
Computer software | Configuration and monitoring software tool | CX-Drive |
Computer software | Configuration and monitoring software tool | CX-One |
Computer software | Software tool for Energy Saving calculation | €Saver |
Specifications
200 V class
Single-phase: 3G3MX2-_ | B001 | B002 | B004 | B007
2
Three phase model use forced-air-cooling
but single phase model is self cooling. |
B015 | B022 | – | – | – | – | – | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase: 3G3MX2-_ | 2001 | 2002 | 2004 | 2007 | 2015 | 2022 | 2037 | 2055 | 2075 | 2110 | 2150 | ||
Motor kW
2
Based
on a standard 3-Phase standard motor. |
For VT setting | 0.2 | 0.4 | 0.55 | 1.1 | 2.2 | 3.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | |
For CT setting | 0.1 | 0.2 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | ||
Output characteristics |
Inverter capacity kVA | 200 VT | 0.4 | 0.6 | 1.2 | 2.0 | 3.3 | 4.1 | 6.7 | 10.3 | 13.8 | 19.3 | 23.9 |
200 CT | 0.2 | 0.5 | 1.0 | 1.7 | 2.7 | 3.8 | 6.0 | 8.6 | 11.4 | 16.2 | 20.7 | ||
240 VT | 0.4 | 0.7 | 1.4 | 2.4 | 3.9 | 4.9 | 8.1 | 12.4 | 16.6 | 23.2 | 28.6 | ||
240 CT | 0.3 | 0.6 | 1.2 | 2.0 | 3.3 | 4.5 | 7.2 | 10.3 | 13.7 | 19.5 | 24.9 | ||
Rated output current (A) at VT | 1.2 | 1.9 | 3.5 | 6.0 | 9.6 | 12.0 | 19.6 | 30.0 | 40.0 | 56.0 | 69.0 | ||
Rated output current (A) at CT | 1.0 | 1.6 | 3.0 | 5.0 | 8.0 | 11.0 | 17.5 | 25.0 | 33.0 | 47.0 | 60.0 | ||
Max. output voltage | Proportional to input voltage: 0 … 240 V | ||||||||||||
Max. output frequency | 400 Hz | ||||||||||||
Power supply |
Rated input voltage and frequency | Single-phase 200… 240 V 50/60 Hz3-phase 200… 240 V 50/60 Hz | |||||||||||
Allowable voltage fluctuation | –15% … +10% | ||||||||||||
Allowable frequency fluctuation | 5% | ||||||||||||
Braking torque | At short-time deceleration At capacitor feedback |
100%: 50Hz 50%: 60Hz |
70%: 50Hz 50%: 60Hz |
Approx 20% | – | ||||||||
Cooling method | Self cooling | Forced-air-cooling |
400 V class
Three-phase: 3G3MX2-_ | 4004 | 4007 | 4015 | 4022 | 4030 | 4040 | 4055 | 4075 | 4110 | 4150 | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Motor kW |
For VT setting | 0.75 | 1.5 | 2.2 | 3.0 | 4.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | |
For CT setting | 0.4 | 0.75 | 1.5 | 2.2 | 3.0 | 4.0 | 5.5 | 7.5 | 11 | 15 | ||
Output characteristics |
Inverter capacity kVA | 380 VT | 1.3 | 2.6 | 3.5 | 4.5 | 5.7 | 7.3 | 11.5 | 15.1 | 20.4 | 25.0 |
380 CT | 1.1 | 2.2 | 3.1 | 3.6 | 4.7 | 6.0 | 9.7 | 11.8 | 15.7 | 20.4 | ||
480 VT | 1.7 | 3.4 | 4.4 | 5.7 | 7.3 | 9.2 | 14.5 | 19.1 | 25.7 | 31.5 | ||
480 CT | 1.4 | 2.8 | 3.9 | 4.5 | 5.9 | 7.6 | 12.3 | 14.9 | 19.9 | 25.7 | ||
Rated output current (A) at VT | 2.1 | 4.1 | 5.4 | 6.9 | 8.8 | 11.1 | 17.5 | 23.0 | 31.0 | 38.0 | ||
Rated output current (A) at CT | 1.8 | 3.4 | 4.8 | 5.5 | 7.2 | 9.2 | 14.8 | 18.0 | 24.0 | 31.0 | ||
Max. output voltage | Proportional to input voltage: 0 … 480 V | |||||||||||
Max. output frequency | 400 Hz | |||||||||||
Power supply |
Rated input voltage and frequency | 3-phase 380 … 480 V 50/60 Hz | ||||||||||
Allowable voltage fluctuation | –15% … +10% | |||||||||||
Allowable frequency fluctuation | 5% | |||||||||||
Braking torque | At short-time deceleration At capacitor feedback |
100%: 50Hz 50%: 60Hz |
70%: 50Hz 50%: 60Hz |
– | ||||||||
Cooling method | Self cooling | Forced-air-cooling |
Dimensions
Standard models
Voltage class | Inverter model | Dimensions in mm | Weight (kg) | |||
---|---|---|---|---|---|---|
H | W | D | ||||
Single-phase 200 V | 3G3MX2-AB001-E | 128 | 68 | 109 | 1.0 | ![]() |
3G3MX2-AB002-E | 1.0 | |||||
3G3MX2-AB004-E | 122.5 | 1.1 | ||||
3G3MX2-AB007-E | 128 | 108 | 170.5 | 1.4 | ||
3G3MX2-AB015-E | 1.8 | |||||
3G3MX2-AB022-E | 1.8 | |||||
Three-phase 200 V | 3G3MX2-A2001-E | 128 | 68 | 109 | 1.0 | |
3G3MX2-A2002-E | 1.0 | |||||
3G3MX2-A2004-E | 122.5 | 1.1 | ||||
3G3MX2-A2007-E | 145.5 | 1.2 | ||||
3G3MX2-A2015-E | 128 | 108 | 170.5 | 1.6 | ||
3G3MX2-A2022-E | 1.8 | |||||
3G3MX2-A2037-E | 128 | 140 | 170.5 | 2.0 | ||
3G3MX2-A2055-E | 260 | 140 | 155 | 3.0 | ||
3G3MX2-A2075-E | 3.4 | |||||
3G3MX2-A2110-E | 296 | 180 | 175 | 5.1 | ||
3G3MX2-A2150-E | 350 | 220 | 175 | 7.4 | ||
Three-phase 400 V | 3G3MX2-A4004-E | 128 | 108 | 143.5 | 1.5 | |
3G3MX2-A4007-E | 170.5 | 1.6 | ||||
3G3MX2-A4015-E | 1.8 | |||||
3G3MX2-A4022-E | 1.9 | |||||
3G3MX2-A4030-E | 1.9 | |||||
3G3MX2-A4040-E | 128 | 140 | 170.5 | 2.1 | ||
3G3MX2-A4055-E | 260 | 155 | 3.5 | |||
3G3MX2-A4075-E | 3.5 | |||||
3G3MX2-A4110-E | 296 | 180 | 175 | 4.7 | ||
3G3MX2-A4150-E | 5.2 |
Finless models
Voltage class | Inverter model | Dimensions in mm | Weight (kg) | |||
---|---|---|---|---|---|---|
H | W | D | ||||
Single-phase 200 V | 3G3MX2-AB001-P-E | 128 | 68 | 103 | 1.1 | ![]() |
3G3MX2-AB002-P-E | ||||||
3G3MX2-AB004-P-E | ||||||
3G3MX2-AB007-P-E | 128 | 108 | 123 | 1.8 | ||
3G3MX2-AB015-P-E | ||||||
3G3MX2-AB022-P-E | ||||||
Three-phase 200 V | 3G3MX2-A2001-P-E | 128 | 68 | 103 | 1.1 | |
3G3MX2-A2002-P-E | ||||||
3G3MX2-A2004-P-E | ||||||
3G3MX2-A2007-P-E | ||||||
3G3MX2-A2015-P-E | 128 | 108 | 123 | 1.8 | ||
3G3MX2-A2022-P-E | ||||||
3G3MX2-A2037-P-E | 128 | 140 | 123 | 2.1 | ||
Three-phase 400 V | 3G3MX2-A4004-P-E | 128 | 108 | 123 | 1.8 | |
3G3MX2-A4007-P-E | ||||||
3G3MX2-A4015-P-E | ||||||
3G3MX2-A4022-P-E | ||||||
3G3MX2-A4030-P-E | ||||||
3G3MX2-A4040-P-E | 128 | 140 | 123 | 2.1 |
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Ota minuun yhteyttä MX2

Kiitos yhteydenotostasi. Otamme teihin yhteyttä mahdollisimman pian.
Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.
DownloadTarjous MX2
Tällä lomakkeella voit pyytää tarjouksen valitsemastasi tuotteesta. Täytäthän kaikki *-merkityt kentät. Henkilökohtaisia tietojasi käsitellään luottamuksellisesti.

Kiitos tarjouspyynnöstä. Toimitamme tarvittavat tiedot teille mahdollisimman pian.
Meillä on teknisiä ongelmia. Emme ole pystyneet vastaanottamaan lomakettasi. Pahoittelemme ja pyydämme yrittämään uudelleen myöhemmin.
Download